Error code 0xFF09: Motor phase failure

Text ID: 0x27

Motor phase failure monitoring

Error code 0xFF0A: Motor phase failure - phase U

Text ID: 0x28

Motor phase failure monitoring

Error code 0xFF0B: Motor phase failure - phase V

Text ID: 0x29

Motor phase failure monitoring

Error code 0xFF0C: Motor phase failure - phase W

Text ID: 0x2A

Motor phase failure monitoring

Cause

Remedies

Response

Multiple motor phases are not

connected.

• Correct the wiring between the

controller and the motor.

• In the case of a false alarm,

increase the threshold values for

monitoring in

0x2D45

|

0x3545

.

Default setting: No response

Monitoring takes place before and

during operation. Both monitoring

modes can trigger an error. For

parameter setting of the two

monitoring modes, see

0x2D45

|

0x3545

.

Cause

Remedies

Response

Motor phase U is not connected.

• Correct the wiring between the

controller and the motor.

• In the case of a false alarm,

increase the threshold values for

monitoring in

0x2D45

|

0x3545

.

Default setting: No response

Monitoring takes place before and

during operation. Both monitoring

modes can trigger an error. For

parameter setting of the two

monitoring modes, see

0x2D45

|

0x3545

.

Cause

Remedies

Response

Motor phase V is not connected.

• Correct the wiring between the

controller and the motor.

• In the case of a false alarm,

increase the threshold values for

monitoring in

0x2D45

|

0x3545

.

Default setting: No response

Monitoring takes place before and

during operation. Both monitoring

modes can trigger an error. For

parameter setting of the two

monitoring modes, see

0x2D45

|

0x3545

.

Cause

Remedies

Response

Motor phase W is not connected.

• Correct the wiring between the

controller and the motor.

• In the case of a false alarm,

increase the threshold values for

monitoring in

0x2D45

|

0x3545

.

Default setting: No response

Monitoring takes place before and

during operation. Both monitoring

modes can trigger an error. For

parameter setting of the two

monitoring modes, see

0x2D45

|

0x3545

.