Motor control & motor settings

5.11

Setting control loops

114

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2900 | 0x3100 - Speed controller: Parameter

0x2901 | 0x3101 - Speed controller: Gain - adaptation

0x2902 | 0x3102 - Speed controller: Load starting value

0x2903 | 0x3103 - Speed: Speed setpoint - filter time

Sub.

Name

Lenze setting

Data type

1

Speed controller: Gain

0.00033 Nm/rpm

UNSIGNED_32

2

Speed controller: Reset time

17.6 ms

UNSIGNED_16

3

Speed controller: Rate time

0.00 ms

UNSIGNED_16

Subindex 1:

Speed controller: Gain

Setting range

(min. value | unit | max. value)

Lenze setting

0.00000

Nm/rpm

20000.00000 0.00033 Nm/rpm

Write access  CINH  OSC  P  RX  TX

Scaling: 1/100000

UNSIGNED_32

Subindex 2:

Speed controller: Reset time

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

6000.0 17.6 ms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16

Subindex 3:

Speed controller: Rate time

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

ms

3.00 0.00 ms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/100

UNSIGNED_16

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

200.00 100.00 %

Write access  CINH  OSC  P  RX  TX

Scaling: 1/100

UNSIGNED_16

Setting range

(min. value | unit | max. value)

Lenze setting

-1000.0

%

1000.0 0.0 %

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

ms

50.0 0.0 ms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16