5 identification data, 0x1000 - device: type, 0x1001 - error memory – Lenze i700 User Manual

Page 280: 0x1008 - ecat: manufacturer's device name, 0x1009 - device: hardware version, 0x100a - device: software version, 0x1018 - ecat: identification data, Identification data, 0x1000, 0x1001

Advertising
background image

9

Diagnostics & error management

9.5

Identification data

280

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.5

Identification data

0x1000 - Device: Type

0x1001 - Error memory

0x1008 - ECAT: Manufacturer's device name

0x1009 - Device: Hardware version

0x100A - Device: Software version

0x1018 - ECAT: Identification data

Selection list

(read only)

0x01020192 Single Servo Axis CiA402
0x02020192 Double Servo Axis CiA402

Write access  CINH  OSC  P  RX  TX

UNSIGNED_32

The error memory displays the error cause in a bit coded manner. It is also possible that several errors are pending

at the same time.

Display area

(min. value | unit | max. value)

Initialisation

0

255 0

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Write access  CINH  OSC  P  RX  TX

STRING(50)

Write access  CINH  OSC  P  RX  TX

STRING(50)

Write access  CINH  OSC  P  RX  TX

STRING(50)

Note:

The fixed identification data depend on the device version of the i700 servo inverter.

Examples of identification data for a double axis are provided below.

Sub.

Name

Lenze setting

Data type

1 ECAT: Vendor ID

59

UNSIGNED_32

2 ECAT: Product code

0x69070002: i700 (Double Inverter,

Safety STO)

UNSIGNED_32

3 ECAT: ESI revision

65542

UNSIGNED_32

4 ECAT: Serial number

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX