3 ready to switch on, Ready to switch on, To the – Lenze i700 User Manual

Page 183: Devi, 7cia402 device profile

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

183

7

CiA402 device profile

7.4

Device control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.2.3

Ready to switch on

This is the device status of the controller after

the device has been initialised successfully and

after the controller has received the

"

Shutdown

" command.

• The process data monitoring is active.
• Communication is possible.
• DC-bus voltage is available.
• The inverter can be parameterised.
• The motor brake, if available, is closed.
• The operation is inhibited.

Bit pattern for the "Ready to switch on" device status in the Statusword (

0x6041

or

0x6841

for axis B):

Bits 15 - 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Warning is

active

Switch on

disabled

Quick stop

Voltage

enabled

Fault active

Operation

enabled

Switched on

Ready to

switch on

X

X

0

1

X

0

0

0

1

Note!

A changeover to this device status is also effected if, in the

Switched on

" or "

Operation

enabled

" device status, the "

Shutdown

" command is activated.

The change to the sequential "

Switched on

" state is effected by activation of the "

Switch

on

" command.

Ready to

switch on

Not ready to

switch on

Switched

on

Operation

enabled

Fault reaction

active

Fault

active

Switch on

disabled

Quick stop

active

Power on

Advertising