2 device identification data, 0x2000 - device: data, 0x2001 - device: name – Lenze i700 User Manual

Page 46: 3 function "optical device recognition, 0x2021 - device: optical recognition, Device identification data, 0x2000 - device: data 0x2001 - device: name, Function "optical device recognition, 0x2000, 0x2001

Advertising
background image

4

Device settings

4.2

Device identification data

46

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2

Device identification data

0x2000 - Device: Data

0x2001 - Device: Name

4.3

Function "Optical device recognition"

0x2021 - Device: Optical recognition

Type code (Lenze ID), serial number and manufacturing date of the device

Sub.

Name

Lenze setting

Data type

1 Device: Product designation

STRING(50)

2 Device: Serial number

STRING(50)

3 Device: Manufacturing date

STRING(50)

Write access  CINH  OSC  P  RX  TX

Any device name (e.g. "Wheel drive") can be set in this object for the purpose of device identification.

Write access  CINH  OSC  P  RX  TX

STRING(128)

In the case of applications with multiple interconnected controllers, it may be difficult to locate a device that has

been connected online. The "Optical device recognition" function serves to locate the i700 servo inverter by means

of blinking LEDs.

• A setting of "1: Start" in subindex 1 activates the function:

• The two LEDs "RDY" and "ERR" on the front of the i700 servo inverter will blink for the time period set in

subindex 2 with a blinking frequency of 20 Hz. Then the function is deactivated automatically.

• The LEDs on the RJ45 sockets are not used for this function.

• If the function is reactivated within the time set, the time is extended correspondingly.

• With the setting "0: Stop" in subindex 1 the function can be aborted/deactivated prematurely.

Sub.

Name

Lenze setting

Data type

1

Start optical recognition

0: Stop

UNSIGNED_8

2

Optical recognition: Blinking time

5 s

UNSIGNED_16

Subindex 1:

Start optical recognition

Selection list

(Lenze setting printed in bold)

0 Stop
1 Start

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Subindex 2:

Optical recognition: Blinking time

Setting range

(min. value | unit | max. value)

Lenze setting

0

s

6000 5 s

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

Advertising