11.1

Table of attributes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x3549

Motor temperature monitoring: Parameter
1: Motor temperature monitoring: Sensor type

UNSIGNED_8

-

P

2: Motor temperature monitoring: Response

UNSIGNED_8

-

P

3: Motor temperature monitoring: Warning threshold

INTEGER_16

1/10

P

4: Motor temperature monitoring: Error threshold

INTEGER_16

1/10

P

5: Motor temperature monitoring: Actual motor temperature

INTEGER_16

1/10

OSC

Tx

6: Thermal sensor characteristic: Grid point 1 - temperature

INTEGER_16

1/10

P

7: Thermal sensor characteristic: Grid point 2 - temperature

INTEGER_16

1/10

P

8: Thermal sensor characteristic: grid point 1 - resistance

INTEGER_16

-

P

9: Thermal sensor characteristic: grid point 2 - resistance

INTEGER_16

-

P

0x354C

Motor utilisation (I²xt): Parameter for the thermal model
1: Motor utilisation (I²xt): Thermal time constant - winding

UNSIGNED_16

-

P

2: Motor utilisation (I²xt): Thermal time constant - laminations

UNSIGNED_16

-

P

3: Motor utilisation (I²xt): Influence of the winding

UNSIGNED_8

-

P

4: Motor utilisation (I²xt): Starting value

UNSIGNED_16

-

P

0x354D

Motor utilisation (I²xt): User-definable characteristic
1: I²xt: x1 = n01/nN (n01 ~ 0)

UNSIGNED_16

-

P

2: I²xt: y1 = i01/iN (x = n01 ~ 0)

UNSIGNED_16

-

P

3: I²xt: x2 = n02/nN (n02 = limit - reduced cooling)

UNSIGNED_16

-

P

4: I²xt: y2 = i02/iN (x = n02 = limit - reduced cooling)

UNSIGNED_16

-

P

5: I²xt: x3 = n03/nN (n03 = rated speed)

UNSIGNED_16

-

P

6: I²xt: y3 = i03/iN (x = n03 = rated speed)

UNSIGNED_16

-

P

7: I²xt: x4 = n04/nN (n04 = limit - field weakening)

UNSIGNED_16

-

P

8: I²xt: y4 = i04/iN (x = n04 = limit - field weakening)

UNSIGNED_16

-

P

0x354E

Motor utilisation (I²xt): Motor overload warning threshold

UNSIGNED_16

-

P

0x354F

Motor utilisation (I²xt): Actual utilisation

UNSIGNED_16

-

OSC

Tx

0x3550

Motor utilisation (I²xt): Motor overload error
1: Motor utilisation (I²xt): Response

UNSIGNED_8

-

P

2: Motor utilisation (I²xt): Error threshold

UNSIGNED_16

-

P

0x3581

Counter: Operating time
1: Device: Operating time

UNSIGNED_32

-

2: Device: Power-on time

UNSIGNED_32

-

0x3582

Motor: Actual voltage - Veff, phase-phase

UNSIGNED_32

1/10

OSC

Tx

0x3583

Motor: Phase currents
1: Zero system current

INTEGER_32

1/100

OSC

Tx

2: Current - phase U

INTEGER_32

1/100

OSC

Tx

3: Current - phase V

INTEGER_32

1/100

OSC

Tx

4: Current - phase W

INTEGER_32

1/100

OSC

Tx

0x3584

Heatsink temperature
1: Heatsink temperature: Actual temperature

INTEGER_16

1/10

OSC

2: Heatsink temperature: Warning threshold

INTEGER_16

1/10

P

3: Heatsink temperature: Threshold - switch-on fan

INTEGER_16

1/10

P

4: Heatsink temperature: Threshold - switch-off fan

INTEGER_16

1/10

P

0x358A

Speed monitoring: Actual speed error

INTEGER_32

-

OSC

Tx

0x35D0

Field: Values
1: Field: Actual field

UNSIGNED_16

-

OSC

Tx

2: Field: Setpoint field

UNSIGNED_16

-

OSC

Tx

Index

Name

Data type

Scaling

Attributes

Greyed out = read only