2 sdo abort codes, Sdo abort codes, 3communication with the controller – Lenze i700 User Manual
Page 27
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
27
3
Communication with the controller
3.3
Parameter data transfer (SDO communication)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.3.2
SDO abort codes
If an SDO request is evaluated negatively, a corresponding abort code is output:
3.3.3
ESI: EtherCAT Slave Information file (device description)
The EtherCAT Slave Information file (EtherCAT Device Description file) contains all information
about the device (operating modes, parameters, …).
• The EtherCAT Slave Information file is integrated by the EtherCAT network configuration tool in
order to be able to configure and commission the devices.
• Part of the information contained in the EtherCAT Slave Information file can be uploaded online
by the EtherCAT master by accessing the EtherCAT EEPROM of the device. The description of the
object directory can also be identified online.
SDO abort code
Description
0x0000 0000
No error
0x0503 0000
The status of the toggle bit has not changed.
0x0504 0000
SDO protocol time-out
0x0504 0005
The space in the main memory is not sufficient.
0x0601 0000
Access to object not supported.
0x0601 0001
Read access to a write-protected object.
0x0601 0002
Write access to a write-protected object.
0x0602 0000
Object is not listed in the object directory.
0x0604 0041
Object cannot be mapped into the PDO.
0x0604 0042
The number and/or length of the mapped objects would exceed the PDO length.
0x0604 0043
General parameter incompatibility
0x0604 0047
General internal device incompatibility
0x0606 0000
Access has failed because of hardware errors.
0x0607 0010
Wrong data type or parameter length.
0x0607 0012
Wrong data type (parameter length is too large).
0x0607 0013
Wrong data type (parameter length is too small).
0x0609 0011
Subindex does not exist.
0x0609 0030
The value range for parameters is too large (only for write access).
0x0609 0031
The parameter value is too high.
0x0609 0032
The parameter value is too low.
0x0800 0000
General error
0x0800 0020
Data cannot be transferred or saved to the application.
0x0800 0021
Data cannot be transferred or saved to the application because of local control.
0x0800 0022
Data cannot be transferred/saved to the application because of current device state.