7

CiA402 device profile

7.4

Device control

176

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.1.5

Disable operation

 From all states

 Power section inhibited (pulse inhibit)

 Power section enabled

This command serves to inhibit the enabled

operation again.

• The pulse inhibit is set.
• If automatic brake operation is activated,

the parameterised brake closing time is

observed: The system waits until the brake

is applied before the pulse inhibit is set.

• A changeover back to the "

Switched on

"

device status takes place.

Bit pattern for the "Disable operation" command in the Controlword (

0x6040

or

0x6840

for axis B):

Bits 15 - 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Fault reset

Control bits depending on the operating mode

Enable

operation

Activate quick

stop

Enable voltage

Switch on

X

0

X

X

X

0

1

1

1

1
2

0

Ready to

switch on

Not ready to

switch on

Switched

on

Operation

enabled

Fault reaction

active

Fault

Switch-on

disabled

Quick stop

active

Power-on