0x2944, 0x3144, 0x2944:1 – Lenze i700 User Manual

Page 134: 0x3144:1, 0x2944:2, 0x3144:2, 0x2944:3, 0x3144:3, For ax, 5motor control & motor settings

Advertising
background image

5

Motor control & motor settings

5.13

Parameterising filter elements in the setpoint path

134

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2944 | 0x3144 - Torque: Notch filter setpoint torque

Note!

Readjust the speed controller after setting the notch filters.

Setting the speed

controller

.

( 113)

For permanent storage, the changed settings must be uploaded to the controller from

the i700 servo inverter.
The »EASY Starter« serves to save the parameter settings of the i700 servo inverter as

parameter file (*.gdc). In the »PLC Designer«, this file can then be imported in the

corresponding axis.

Saving changed parameters safe against mains failure

( 60)

Sub.

Name

Lenze setting

Data type

1

Notch filter 1: Frequency

200.0 Hz

UNSIGNED_16

2

Notch filter 1: Bandwidth

20.0 Hz

UNSIGNED_16

3

Notch filter 1: Damping

0 db

UNSIGNED_8

4

Notch filter 2: Frequency

400.0 Hz

UNSIGNED_16

5

Notch filter 2: Bandwidth

40.0 Hz

UNSIGNED_16

6

Notch filter 2: Damping

0 db

UNSIGNED_8

Subindex 1:

Notch filter 1: Frequency

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

Hz

1000.0 200.0 Hz

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16

Subindex 2:

Notch filter 1: Bandwidth

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

Hz

500.0 20.0 Hz

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16

Subindex 3:

Notch filter 1: Damping

Setting range

(min. value | unit | max. value)

Lenze setting

0

dB

100 0 db

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Subindex 4:

Notch filter 2: Frequency

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

Hz

1000.0 400.0 Hz

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16

Subindex 5:

Notch filter 2: Bandwidth

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

Hz

500.0 40.0 Hz

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16

Advertising