0x6041 | 0x6841 - Statusword

0x605A | 0x685A - Quick stop option code

Status word from the drive

Display area

(min. value | unit | max. value)

Initialisation

0

65535

Value is bit-coded:

Info

Bit 0 Ready to switch on
Bit 1 Switched on
Bit 2 Operation enabled
Bit 3 Trouble active
Bit 4 Voltage enabled
Bit 5 Quick stop
Bit 6 Switch on disabled
Bit 7 Warning is active
Bit 8 Deactivate RPDOs

Cyclic PDOs have been deactivated in

0x2824

(or

0x3024

for axis B).

Bit 9 Remote

Drive can receive commands via EtherCAT.

Bit 10 Target reched

The actual position is located in the window (

0x6067

or

0x6867

for axis B).

Bit 11 Internal limitation is active

For details see Lenze status word (

0x2831

or

0x3031

for

axis B).

Bit 12 Drive Follows Command

Operation is enabled and no test mode is activated (no

internal setpoint generation active).

Bit 13 Following error

The position could not be approached.

Bit 14 Brake released
Bit 15 STO is not active

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

Device status after exiting the quick stop ramp

2 = automatic changeover to the "

Switch-on disabled

" device status

6 = the axis remains in the "

Quick stop active

" device status.

Setting range

(min. value | unit | max. value)

Lenze setting

2

6 2

Write access  CINH  OSC  P  RX  TX

INTEGER_16