6 setting the field weakening controller (asm), Setting the field weakening controller (asm), 0x29e0 – Lenze i700 User Manual

Page 119: 0x31e0, Calculate field weakening controller parameters, 5motor control & motor settings

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

119

5

Motor control & motor settings

5.11

Setting control loops

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.11.6

Setting the field weakening controller (ASM)

Since the controlled system gain changes with the speed, the field weakening controller is corrected

via the speed.
For the automatic calculation of the controller parameters, the "Field weakening controller:

Calculate controller parameters" function is provided via object

0x2822

(or

0x3022

for axis B).

0x29E0 | 0x31E0 - Field weakening controller: Parameter

Subindex 2:

Field controller: Reset time

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

6000.0 15.1 ms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16

Equations for calculating the gain and the reset time

Axis A

Axis B

Symbol Description

Dimension unit

0x29E0:1 0x31E0:1

V

p

Field weakening controller gain

Vs/V

-

-

V

path_Fs

Gain of the controlled path

-

-

p Number of pole pairs

-

-

n

transition

Speed at which the field weakening is approximately

initiated.

rpm

0x29E0:2 0x31E0:2

T

n

Field weak. contr. reset time

s

-

-

T

EF

Equivalent time constant of the field control loop

0x29E3

0x31E3

T

filter

Filter time constant for the required voltage

s

-

-

T

r

Motor rotor time constant

-

-

L

r

Motor rotor inductance

0x2C02:2 0x3402:2

L

h

Mutual motor inductance (ASM)

H

0x2C01:3 0x3401:3

L

ss

Motor stator leakage inductance (ASM) or

motor stator inductance (SM)

H

0x2C02:1 0x3402:1

R

r

Motor rotor resistance (ASM)

Ω

V

p

0

=

V

Distance_Fs

p n

Transition

60

-------

=

T

n

4

V

Distance_Fs

60

-----------------------------

T

EF

T

Filter

+

(

)

=

T

EF

T

r

L

r

R

r

-----

L

h

L

ss

+

R

r

------------------

=

=

Sub.

Name

Lenze setting

Data type

1

Field weakening controller: Gain

0.000 Vs/V

UNSIGNED_32

2

Field weakening controller: Reset time

2000.0 ms

UNSIGNED_32

Subindex 1:

Field weakening controller: Gain

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

Vs/V

2147483.647 0.000 Vs/V

Write access  CINH  OSC  P  RX  TX

Scaling: 1/1000

UNSIGNED_32