Lenze i700 User Manual

Page 8

Advertising
background image

Contents

8

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.11 Touch probe (TP) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

226

7.11.1

Default mapping _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

227

7.11.2

General functional principle _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

228

7.11.3

Filtering the touch probe signal _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

229

0x2500 - Touch probe (TP): Debounce time

7.11.4

Compensation of runtime delays _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

229

0x2D00 | 0x3500 - Touch probe (TP): Dead time compensation

7.11.5

Touch probe function _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

231

0x60B8 | 0x68B8 - Touch probe function

7.11.6

Touch probe status _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

232

0x60B9 | 0x68B9 - Touch probe status

7.11.7

Time stamps and positions detected _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

233

0x2D01 | 0x3501 - Touch probe (TP): Time stamp
0x60BA | 0x68BA - Touch probe pos1 pos value
0x60BB | 0x68BB - Touch probe pos1 neg value
0x60BC | 0x68BC - Touch probe pos2 pos value
0x60BD | 0x68BD - Touch probe pos2 neg value

8

Monitoring functions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

235

8.1

24-V supply voltage monitoring _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

235

8.2

Monitoring of the power section and device utilisation (Ixt) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

236

0x2D40 | 0x3540 - Ixt utilisation

8.3

Monitoring of the heatsink temperature _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

239

0x2D84 | 0x3584 - Heatsink temperature

8.4

Monitoring of the motor utilisation (I²xt) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

241

0x2D4E | 0x354E - Motor utilisation (I²xt): Motor overload warning threshold
0x2D4F | 0x354F - Motor utilisation (I²xt): Actual utilisation
0x2D50 | 0x3550 - motor utilisation (I²xt): Motor overload error
0x2D4C | 0x354C - Motor utilisation (I²xt): Parameter for the thermal model
0x2D4D | 0x354D - Motor utilisation (I²xt): User-definable characteristic

8.4.1

Example of how to enter the characteristic for standard and servo motors _ _ _ _ _ _ _

246

8.4.2

UL 508-compliant I²xt motor overload monitoring _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

248

8.5

Motor temperature monitoring _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

250

0x2D49 | 0x3549 - Motor temperature monitoring: Parameters

8.5.1

Spec. charact. curve for motor temperature sensor _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

252

8.6

Motor speed monitoring _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

253

0x2D44 | 0x3544 - Motor speed monitoring

8.7

Motor phase failure monitoring _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

254

0x2D45 | 0x3545 - Motor phase failure detection

8.7.1

Limits of the motor phase failure monitoring _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

255

8.7.2

Monitoring 2: In the "enable operation" state transition _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

256

8.7.3

Monitoring 1: In "operation enabled" status _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

256

8.7.4

Monitoring with regard to short circuit and earth fault _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

257

8.8

Monitoring of the ultimate motor current _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

258

0x2D46 | 0x3546 - Monitoring: Ultimate motor current