0x1605 - rpdo-->axis a: freely configurable (user), 0x1606 - rpdo-->axis a: torque limits, 0x1607 - rpdo --> axis a: speed limits – Lenze i700 User Manual

Page 315: 0x1610, 0x1606, 0x1605, 0x1607, 11 appendix

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

315

11

Appendix

11.3

Communication objects

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x1605 - RPDO-->Axis A: Freely configurable (user)

0x1606 - RPDO-->Axis A: Torque limits

0x1607 - RPDO --> Axis A: Speed Limits

0x1610 - RPDO-->Axis B: Cyclic sync position mode (csp)

PDO mapping object freely configurable by the user for process data from the controller to the servo inverter

Sub.

Name

Lenze setting

Data type

1 (user) RPDO-->A: xxxx freely configurable object 1

0x00000000

UNSIGNED_32

2 (user) RPDO-->A: xxxx freely configurable object 2

0x00000000

UNSIGNED_32

3 (user) RPDO-->A: xxxx freely configurable object 3

0x00000000

UNSIGNED_32

4 (user) RPDO-->A: xxxx freely configurable object 4

0x00000000

UNSIGNED_32

5 (user) RPDO-->A: xxxx freely configurable object 5

0x00000000

UNSIGNED_32

6 (user) RPDO-->A: xxxx freely configurable object 6

0x00000000

UNSIGNED_32

7 (user) RPDO-->A: xxxx freely configurable object 7

0x00000000

UNSIGNED_32

8 (user) RPDO-->A: xxxx freely configurable object 8

0x00000000

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Fixed, preconfigured PDO mapping object for torque limits

Sub.

Name

Lenze setting

Data type

1 (torque) RPDO-->A: 0x60E0 (Positive torque limit value)

0x60E00010

UNSIGNED_32

2 (torque) RPDO-->A: 0x60E1 (Negative torque limit value)

0x60E10010

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Sub.

Name

Lenze setting

Data type

1 (Speed) RPDO-->A: 0x2946/1 (upper speed limit)

692453664

UNSIGNED_32

2 (Speed) RPDO-->A: 0x2946/2 Lower speed limit

692453920

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Fixed, preconfigured PDO mapping object for

"Cyclic sync position mode"

Sub.

Name

Lenze setting

Data type

1 (csp) RPDO-->B: 0x6840 (Controlword)

0x68400010

UNSIGNED_32

2 (csp) RPDO-->B: 0x3030 (Lenze control word)

0x30300010

UNSIGNED_32

3 (csp) RPDO-->B: 0x6860 (Modes of operation)

0x68600008

UNSIGNED_32

4 (csp) RPDO-->B: 0x68B2 (Torque: Offset)

0x68B20010

UNSIGNED_32

5 (csp) RPDO-->B: 0x687A (Target position)

0x687A0020

UNSIGNED_32

6 (csp) RPDO-->B: 0x68B1 (Velocity offset)

0x68B10020

UNSIGNED_32

7 (csp) RPDO-->B: 0x3102 speed controller - load starting value 0x31020010

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Advertising