0x6076 | 0x6876 - motor rated torque, 0x6076, 0x6876 – Lenze i700 User Manual

Page 84: 5motor control & motor settings

Advertising
background image

5

Motor control & motor settings

5.8

Setting the motor parameters for the servo control

84

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x6076 | 0x6876 - Motor rated torque

The rated motor torque set here serves as a reference value for the following objects:

• 0x6071 | 0x6872 - Target torque

• 0x6072 | 0x6872 - Max. torque

• 0x6074 | 0x6874 - Torque demand

• 0x6077 | 0x6877 - Torque actual value

• 0x60B2 | 0x68B2 - Torque offset

• 0x60E0 | 0x68E0 - Positive torque limit value

• 0x60E1 | 0x68E1 - Negative torque limit value

• 0x2DD6 | 0x35D6 - Torque: Filter cascade

Setting range

(min. value | unit | max. value)

Lenze setting

0.001

Nm

1000.000 0.600 Nm

Write access  CINH  OSC  P  RX  TX

Scaling: 1/1000

UNSIGNED_32

Advertising