5

Motor control & motor settings

5.9

Setting the feedback system for the servo control

86

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.9.1

General settings

Encoder open-circuit monitoring
In the Lenze setting the resolver/encoder cable is monitored for open circuit.

When does the open-circuit monitoring system respond?

0x2C45 | 0x3445 - open circuit in the feedback system: Response

Display parameter

0x2C46 | 0x3446 - feedback system: Specifiable number of revolutions

Danger!

If the encoder/resolver is used as motor encoder:

Safe operation of the motor is no longer ensured in the event of an error!

• For safety reasons, always select "Fault" (Lenze setting) as a response for the (open-

circuit) monitoring of the encoder/resolver!

• In order to prevent interference injections when an encoder is used, only use shielded

motor and encoder cables!

Resolver

Multi encoder

• If there is an open circuit in the encoder cable.

• If the impedance of the resolver is too high.

• In the case of interference injections (EMC

interferences).

• If there is an open circuit in the encoder cable.

If there is an open circuit in the encoder cable, the response set here is triggered.

Selection list

(Lenze setting printed in bold)

Info

0 No response
1 Fault

• In the device statuses "not ready to start" and "switch-

on inhibited", a warning is output.

• In all other device statuses, the error response set

here is executed.

2 Warning

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

From version 01.03

Is set by the firmware according to the available version:

0: No absolute value encoder (sin/cos encoder) or resolver with number of pole pairs > 1

1: Hiperface encoder SingleTurn or resolver with number of pole pairs = 1

>1: Hiperface encoder MultiTurn

Display area

(min. value | unit | max. value)

Initialisation

0

65535

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16