Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

185

7

CiA402 device profile

7.4

Device control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.2.5

Operation enabled

This device status represents normal

operation. The operation in the operating

mode selected is enabled and no errors are

pending.

• Only the parameters of the inverter can be

changed which do not require controller

inhibit.

• A possibly available motor brake is

released if the automatic operating mode

of the

Holding brake control

is activated.

• The drive control is working.

Bit pattern for the "Operation enabled" device status in the Statusword (

0x6041

or

0x6841

for axis B):

Bits 15 - 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Warning is

active

Switch on

disabled

Quick stop

Voltage

enabled

Fault active

Operation

enabled

Switched on

Ready to

switch on

X

X

0

1

X

0

1

1

1

Ready to

switch on

Not ready to

switch on

Switched

on

Operation

enabled

Fault reaction

active

Fault

active

Switch on

disabled

Quick stop

active

Power on