0x1c32 - sync manager 2 (rpdo-->device): parameter, 0x1c33 - sync manager 3 (device-->tpdo): parameter, 0x1c13 – Lenze i700 User Manual

Page 323: 0x1c32, 0x1c33, 11 appendix

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

323

11

Appendix

11.3

Communication objects

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x1C13 - Sync Manager 3 (RPDO-->Device): PDO mapping

0x1C32 - Sync Manager 2 (RPDO-->Device): Parameter

0x1C33 - Sync Manager 3 (Device-->TPDO): Parameter

Sub.

Name

Lenze setting

Data type

1 SM3 (Device-->TPDO): Assignment PDO 1

0x1A00

UNSIGNED_16

2 SM3 (Device-->TPDO): Assignment PDO 2

0x1A04

UNSIGNED_16

3 SM3 (Device-->TPDO): Assignment PDO 3

0x1A06

UNSIGNED_16

4 SM3 (Device-->TPDO): Assignment PDO 4

0x1A10

UNSIGNED_16

5 SM3 (Device-->TPDO): Assignment PDO 5

0x1A14

UNSIGNED_16

6 SM3 (Device-->TPDO): Assignment PDO 6

0x1A16

UNSIGNED_16

7 SM3 (Device-->TPDO): PDO assignment 7

0x0000

UNSIGNED_16

8 SM3 (Device-->TPDO): PDO assignment 8

0x0000

UNSIGNED_16

Write access  CINH  OSC  P  RX  TX

Sub.

Name

Lenze setting

Data type

1 SM2 (RPDO-->Device): Sync type

0: Free Run

UNSIGNED_16

2 SM2 (RPDO-->Device): Cycle time

250000 ns

UNSIGNED_32

3 SM2 (RPDO-->Device): Shift time

0 ns

UNSIGNED_32

4 SM2 (RPDO-->Device): Supported sync types

0x0825

UNSIGNED_16

5 SM2 (RPDO-->Device): Min. cycle time

125000 ns

UNSIGNED_32

6 SM2 (RPDO-->Device): Signal processing time

0 ns

UNSIGNED_32

9 SM2 (RPDO-->Device): Delay time

0 ns

UNSIGNED_32

11 SM2 (RPDO-->Device): Counter - missing events

UNSIGNED_16

12 SM2 (RPDO-->Device): Cycle time too short

UNSIGNED_16

32 SM2 (RPDO-->Device): Sync error

BOOL

Sub.

Name

Lenze setting

Data type

1 SM3 (Device-->TPDO): Sync type

0: Free Run

UNSIGNED_16

2 SM3 (Device-->TPDO): Cycle time

250000 ns

UNSIGNED_32

3 SM3 (Device-->TPDO): Shift time

62500 ns

UNSIGNED_32

4 SM3 (Device-->TPDO): Supported sync types

0x0825

UNSIGNED_16

5 SM3 (Device-->TPDO): Min. cycle time

125000 ns

UNSIGNED_32

6 SM3 (Device-->TPDO): Signal processing time

0 ns

UNSIGNED_32

9 SM3 (Device-->TPDO): Delay time

0 ns

UNSIGNED_32

11 SM3 (Device-->TPDO): Counter - missing events

UNSIGNED_16

12 SM3 (Device-->TPDO): Cycle time too short

UNSIGNED_16

32 SM3 (Device-->TPDO): Sync error

BOOL