0x29e4 | 0x31e4 - voltage reserve range, 0x29e1, 0x31e1 – Lenze i700 User Manual

Page 120: 0x29e2, 0x31e2, 0x29e3, 0x31e3, 0x29e4, 0x31e4, 5motor control & motor settings

Advertising
background image

5

Motor control & motor settings

5.11

Setting control loops

120

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x29E1 | 0x31E1 - field: Field set value limitation

0x29E2 | 0x31E2 - DC link circuit voltage: Filter time

0x29E3 | 0x31E3 - motor: Actual voltage - filter time

0x29E4 | 0x31E4 - Voltage reserve range

Subindex 2:

Field weakening controller: Reset time

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

240000.0 2000.0 ms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_32

Setting range

(min. value | unit | max. value)

Lenze setting

5.00

%

100.00 100.00 %

Write access  CINH  OSC  P  RX  TX

Scaling: 1/100

UNSIGNED_16

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

1000.0 25.0 ms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

1000.0 25.0 ms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16

From version 01.03

Voltage reserve range at the transition point to the field weakening

• Only relevant for servo control for asynchronous motor (selection "2" in

0x2C00

or

0x3400

for axis B).

Setting range

(min. value | unit | max. value)

Lenze setting

1

%

20 5 %

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8