2 object description, Object description, 7cia402 device profile – Lenze i700 User Manual

Page 219

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

219

7

CiA402 device profile

7.10

Cyclic sync torque mode (cst)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.10.2

Object description

The following two tables provide an overview of the most important objects for this operating

mode (without motor parameters, motor control parameters, and feedback parameters).
All objects correspond to the CiA402 specification, but some of them have only a restricted value

range.

Objects described in other chapters:

Objects described in this chapter:

Object

Name

Data type

Axis A

Axis B

Lenze control and status word

0x2830

0x3030

Lenze control word

UNSIGNED_16

0x2831

0x3031

Lenze status word

UNSIGNED_16

Device control

0x6040

0x6840

Controlword

UNSIGNED_16

0x6060

0x6860

Operating mode: Selection

INTEGER_8

0x6041

0x6841

Statusword

UNSIGNED_16

0x6061

0x6861

Modes of operation display

INTEGER_8

Parameters for actuation of the position control

0x6064

0x6864

Position actual value

INTEGER_32

Cyclic sync position mode (csp)

0x60C2

0x68C2

Interpolation time period

RECORD

Cyclic sync velocity mode (csv)

0x606C

0x686C

Velocity actual value

INTEGER_32

Set motor parameters manually

0x6075

0x6875

Motor rated current

UNSIGNED_32

0x6076

0x6876

Motor rated torque

UNSIGNED_32

Greyed out = read access only

Object

Name

Data type

Axis A

Axis B

0x2946

0x3146

Cyclic sync torque mode: Speed limitation

RECORD

0x6071

0x6871

Target torque

INTEGER_16

0x6072

0x6872

Max torque

UNSIGNED_16

0x6073

0x6873

Max current

UNSIGNED_16

0x6074

0x6874

Target torque

INTEGER_16

0x6077

0x6877

Torque actual value

INTEGER_16

0x6078

0x6878

Current actual value

INTEGER_16

0x6079

0x6879

DC bus: Actual voltage

UNSIGNED_32

0x60B2

0x68B2

Torque offset

INTEGER_16

Greyed out = read access only

Advertising