11 appendix, 1 table of attributes – Lenze i700 User Manual

Page 301

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

301

11

Appendix

11.1

Table of attributes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x3303

VFC: User-definable V/f characteristic - voltage grid points (y)
1: V/f: y1 = U01 (x = f01)

UNSIGNED_32

1/100

P

2: V/f: y2 = U02 (x = f02)

UNSIGNED_32

1/100

P

3: V/f: y3 = U03 (x = f03)

UNSIGNED_32

1/100

P

4: V/f: y4 = U04 (x = f04)

UNSIGNED_32

1/100

P

5: V/f: y5 = U05 (x = f05)

UNSIGNED_32

1/100

P

6: V/f: y6 = U06 (x = f06)

UNSIGNED_32

1/100

P

7: V/f: y7 = U07 (x = f07)

UNSIGNED_32

1/100

P

8: V/f: y8 = U08 (x = f08)

UNSIGNED_32

1/100

P

9: V/f: y9 = U09 (x = f09)

UNSIGNED_32

1/100

P

10: V/f: y10 = U10 (x = f10)

UNSIGNED_32

1/100

P

11: V/f: y11 = U11 (x = f11)

UNSIGNED_32

1/100

P

0x3304

VFC: Voltage vector control - current setpoint

UNSIGNED_32

1/100

P

0x3305

VFC: Voltage vector control parameter
1: VFC: Voltage vector controller - gain

UNSIGNED_32

1/100

P

2: VFC: Voltage vector controller - reset time

UNSIGNED_32

1/100

P

0x3306

VFC: Voltage boost

UNSIGNED_16

1/10

P

0x3307

VFC: Load adjustment - parameter
1: VFC: Load adjustment - direction of rotation

UNSIGNED_8

-

P

CINH

2: VFC: Load adjustment - value

UNSIGNED_32

1/100

P

0x3308

VFC: Imax controller - parameter
1: VFC: Imax controller - gain

UNSIGNED_32

1/1000

P

2: VFC: Imax controller - reset time

UNSIGNED_32

1/10

P

0x3309

VFC: Slip compensation - parameter
1: VFC: Slip compensation - influence

INTEGER_16

1/100

P

2: VFC: Slip compensation - filter time

UNSIGNED_16

-

P

0x330A

VFC: Oscillation damping - parameter
1: VFC: Oscillation damping - gain

INTEGER_16

-

P

2: VFC: Oscillation damping - filter time

UNSIGNED_16

-

P

3: VFC: Oscillation damping - limitation

UNSIGNED_16

1/10

P

4: VFC: Oscillation damping - final ramp frequency

UNSIGNED_8

-

P

0x330B

VFC: Frequency setpoint

INTEGER_16

1/10

OSC

Tx

0x330C

VFC: Override point of field weakening

INTEGER_16

1/10

P

0x3380

DC-injection braking: Current

UNSIGNED_16

1/100

P

0x33A0

Flying restart: Activate

UNSIGNED_8

-

P

0x33A1

Flying restart: Current

UNSIGNED_16

-

P

0x33A2

Flying restart: Start frequency

INTEGER_16

1/10

P

0x33A3

Flying restart: Integration time

UNSIGNED_16

-

P

0x33A4

Flying restart: Min. deviation

UNSIGNED_16

1/100

P

0x33A5

Flying restart: Delay time

UNSIGNED_16

-

P

0x33A6

Flying restart: Result
1: Flying restart: Determined speed [rpm]

INTEGER_16

-

OSC

Tx

2: Flying restart: Determined speed [n unit]

INTEGER_32

480000/2

31

OSC

Tx

Index

Name

Data type

Scaling

Attributes

Greyed out = read only