3 motor parameters (object descriptions), 0x2c01 | 0x3401 - motor: common parameters, Motor parameters (object descriptions) – Lenze i700 User Manual

Page 81: 0x2c01, 0x3401, 0x2c01:1 0x3401:1, 0x2c01:2 0x3401:2, 0x2c01:3 0x3401:3, 0x2c01:4 0x3401:4, 0x2c01:5 0x3401:5

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

81

5

Motor control & motor settings

5.8

Setting the motor parameters for the servo control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.8.3

Motor parameters (object descriptions)

0x2C01 | 0x3401 - Motor: Common parameters

Sub.

Name

Lenze setting

Data type

1

Motor: Number of pole pairs

UNSIGNED_8

2

Motor: Stator resistance

13.5000 ohms

UNSIGNED_32

3

Motor: Stator leakage inductance

51.000 mH

UNSIGNED_32

4

Motor: Rated speed

4050 rpm

UNSIGNED_16

5

Motor: Rated frequency

270.0 Hz

UNSIGNED_16

6

Motor: Rated power

0.25 kW

UNSIGNED_16

7

Motor: Rated voltage

225 V

UNSIGNED_16

8

Motor: Rated cosine phi

0.80

UNSIGNED_16

9

Motor: Insulation class

4: F (cut-off temperature = 155 °C)

UNSIGNED_8

10

Motor: Designation

STRING(50)

Subindex 1:

Motor: Number of pole pairs

Display area

(min. value | unit | max. value)

Initialisation

0

255

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Subindex 2:

Motor: Stator resistance

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Ohm

125.0000 13.5000 ohms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10000

UNSIGNED_32

Subindex 3:

Motor: Stator leakage inductance

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

mH

500.000 51.000 mH

Write access  CINH  OSC  P  RX  TX

Scaling: 1/1000

UNSIGNED_32

Subindex 4:

Motor: Rated speed

Setting range

(min. value | unit | max. value)

Lenze setting

0

r/min

50000 4050 rpm

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

Subindex 5:

Motor: Rated frequency

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

Hz

1000.0 270.0 Hz

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_16

Subindex 6:

Motor: Rated power

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

kW

655.35 0.25 kW

Write access  CINH  OSC  P  RX  TX

Scaling: 1/100

UNSIGNED_16

Advertising