"PAR_ParamErrorHeader" header type
If the identification "2" is given for the data area type, the error messages are successively arranged

in the following layout within the data area:

Byte offset

0

4

6

... Error code

Index

Subindex

...

Byte

offset

Meaning

Info

0

Error code in accordance with CiA301 or

EtherCAT

SDO abort code which was generated when the object

with the following index/subindex combination was

accessed.

SDO abort codes ( 27)

4

Index of the parameter object

Index of the parameter in the object directory which the

error code belongs to.

6

Subindex of the parameter object

Subindex of the parameter in the object directory which

the error code belongs to.