0x1615 - RPDO-->Axis B: Freely configurable (user)

0x1616 - RPDO-->Axis B: Torque limits

0x1617 - RPDO --> Axis B: Speed limits

0x1A00 - Axis A-->TPDO: Cyclic sync position mode (csp)

PDO mapping object freely configurable by the user for process data from the controller to the servo inverter i700

Sub.

Name

Lenze setting

Data type

1 (user) RPDO-->B: xxxx freely configurable object 1

0x00000000

UNSIGNED_32

2 (user) RPDO-->B: xxxx freely configurable object 2

0x00000000

UNSIGNED_32

3 (user) RPDO-->B: xxxx freely configurable object 3

0x00000000

UNSIGNED_32

4 (user) RPDO-->B: xxxx freely configurable object 4

0x00000000

UNSIGNED_32

5 (user) RPDO-->B: xxxx freely configurable object 5

0x00000000

UNSIGNED_32

6 (user) RPDO-->B: xxxx freely configurable object 6

0x00000000

UNSIGNED_32

7 (user) RPDO-->B: xxxx freely configurable object 7

0x00000000

UNSIGNED_32

8 (user) RPDO-->B: xxxx freely configurable object 8

0x00000000

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Fixed, preconfigured PDO mapping object for torque limits

Sub.

Name

Lenze setting

Data type

1 (torque) RPDO-->B: 0x68E0 (Positive torque limit value)

0x68E00010

UNSIGNED_32

2 (torque) RPDO-->B: 0x68E1 (Negative torque limit value)

0x68E10010

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Sub.

Name

Lenze setting

Data type

1 (Speed) RPDO-->B: 0x3146/1 (upper speed limit)

826671392

UNSIGNED_32

2 (Speed) RPDO-->B: 0x3146/2 (Lower speed limit)

826671648

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Fixed, preconfigured PDO mapping object for

"Cyclic sync position mode"

Sub.

Name

Lenze setting

Data type

1 (csp) A-->TPDO: 0x6041 (Statusword)

0x60410010

UNSIGNED_32

2 (csp) A-->TPDO: 0x2831 (Lenze status word)

0x28310010

UNSIGNED_32

3 (csp) A-->TPDO: 0x6061 (Modes of operation display)

0x60610008

UNSIGNED_32

4 (csp) A-->TPDO: 0x603F (Error code)

0x603F0010

UNSIGNED_32

5 (csp) A-->TPDO: 0x606C (Velocity actual value)

0x606C0020

UNSIGNED_32

6 (csp) A-->TPDO: 0x6077 (Torque actual value)

0x60770010

UNSIGNED_32

7 (csp) A-->TPDO: 0x6064 (Position actual value)

0x60640020

UNSIGNED_32

8 (csp) A-->TPDO: 0x60F4 (Following error actual value)

0x60F40020

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX