6 quick stop is active, Quick stop is active, Quick stop active – Lenze i700 User Manual

Page 186: 7cia402 device profile

Advertising
background image

7

CiA402 device profile

7.4

Device control

186

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.2.6

Quick stop is active

This device status is active if quick stop is

executed or is active.

• Only the parameters of the inverter can be

changed which do not require controller

inhibit.

• The motor brake, if available, is opened.
• The drive control is working.

Bit pattern for the "Quick stop active" device status in the Statusword (

0x6041

or

0x6841

for axis B):

Bits 15 - 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Warning is

active

Switch on

disabled

Quick stop

Voltage

enabled

Fault active

Operation

enabled

Switched on

Ready to

switch on

X

X

0

0

X

0

1

1

1

Note!

The "

Enable operation

" command serves to deactivate an active quick stop again.

Ready to

switch on

Not ready to

switch on

Switched

on

Operation

enabled

Fault reaction

active

Fault

active

Switch on

disabled

Quick stop

active

Power on

Advertising