Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

39

3

Communication with the controller

3.6

Ethernet over EtherCAT (EoE)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Response
GCI Message Qualifier (GMQ) = 0x80 = 0b10000000 = "Response"

GCI header

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

GMT

GSV

GMQ

GTI

SIZE

SIZE

res

res

0x01

0x82

0x80

0x00

0x14

0x00

0x00

0x00

Fixed

Read

parameters

Response

Transactions ID

Length of the user data = 20 bytes

Reserved

User data area P0

Byte 1

Byte 2

Byte 3

Byte 4

Reserved

Data type

Reserved

0x00

0x00

0x02

0x00

INTEGER_16

User data area P1

User data area P2

Byte 1

Byte 2

Byte 3

Byte 4

Byte 1

Byte 2

Byte 3

Byte 4

Index

Reserved

Subindex

Reserved

0x84

0x2D

0x00

0x00

0x01

0x00

0x00

0x00

Index = 0x2D84

Subindex = 1

User data area P3

User data area P4

Byte 1

Byte 2

Byte 3

Byte 4

Byte 1

Byte 2

Byte 3

Byte 4

Parameter value

Reserved

0xAE

0x01

0x00

0x00

0x00

0x00

0x00

0x00

Read value = 0x01AE

= 430 = 43.0 [°C]