294

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2BA5

Flying restart: Delay time

UNSIGNED_16

-

P

0x2BA6

Flying restart: Result
1: Flying restart: Determined speed [rpm]

INTEGER_16

-

OSC

Tx

2: Flying restart: Determined speed [n unit]

INTEGER_32

480000/2

31

OSC

Tx

Axis A - motor settings

0x2C00

Motor control

UNSIGNED_8

-

P

CINH

0x2C01

Motor: Common parameters
1: Motor: Number of pole pairs

UNSIGNED_8

-

2: Motor: Stator resistance

UNSIGNED_32

1/10000

P

3: Motor: Stator leakage inductance

UNSIGNED_32

1/1000

P

4: Motor: Rated speed

UNSIGNED_16

-

P

5: Motor: Rated frequency

UNSIGNED_16

1/10

P

6: Motor: Rated power

UNSIGNED_16

1/100

P

7: Motor: Rated voltage

UNSIGNED_16

-

P

8: Motor: Rated cosine phi

UNSIGNED_16

1/100

P

9: Motor: Insulation class

UNSIGNED_8

-

P

10: Motor: Designation

STRING(50)

-

P

0x2C02

Motor (ASM): Parameter
1: Motor (ASM): Rotor resistance

UNSIGNED_32

1/10000

P

2: Motor (ASM): Mutual inductance

UNSIGNED_32

1/10

P

3: Motor (ASM): Magnetising current

UNSIGNED_16

1/100

P

0x2C03

Motor (SM): Parameter
1: Motor (SM): e.m.f. constant (KELL)

UNSIGNED_32

1/10

P

2: Motor (SM): Pole position

INTEGER_16

1/10

P

3: Motor (SM): Temperature coefficient - magnets (kTN)

INTEGER_16

1/1000

P

4: Motor (SM): Pole position

INTEGER_16

1/10

P

0x2C04

Motor: Lss saturation characteristic - inductance grid points (y)
1: Lss: y1 = L01 (x = 0.00 %)

UNSIGNED_16

-

P

2: Lss: y2 = L02 (x = 6.25 %)

UNSIGNED_16

-

P

3: Lss: y3 = L03 (x = 12.50 %)

UNSIGNED_16

-

P

4: Lss: y4 = L04 (x = 18.75 %)

UNSIGNED_16

-

P

5: Lss: y5 = L05 (x = 25.00 %)

UNSIGNED_16

-

P

6: Lss: y6 = L06 (x = 31.25 %)

UNSIGNED_16

-

P

7: Lss: y7 = L07 (x = 37.50 %)

UNSIGNED_16

-

P

8: Lss: y8 = L08 (x = 42.75 %)

UNSIGNED_16

-

P

9: Lss: y9 = L09 (x = 50.00 %)

UNSIGNED_16

-

P

10: Lss: y10 = L10 (x = 56.25 %)

UNSIGNED_16

-

P

11: Lss: y11 = L11 (x = 62.50 %)

UNSIGNED_16

-

P

12: Lss: y12 = L12 (x = 68.75 %)

UNSIGNED_16

-

P

13: Lss: y13 = L13 (x = 75.00 %)

UNSIGNED_16

-

P

14: Lss: y14 = L14 (x = 81.25 %)

UNSIGNED_16

-

P

15: Lss: y15 = L15 (x = 87.50 %)

UNSIGNED_16

-

P

16: Lss: y16 = L16 (x = 93.25 %)

UNSIGNED_16

-

P

17: Lss: y17 = L17 (x = 100.00 %)

UNSIGNED_16

-

P

18: Motor: Lss saturation characteristic - activation

UNSIGNED_16

-

P

0x2C05

Motor: Lss saturation charcteristic - reference for current grid points (x)

UNSIGNED_16

1/10

P

Index

Name

Data type

Scaling

Attributes