3 wiring check by means of manual test modes, 0x2835 | 0x3035 - manual test mode: settings, Wiring check by means of manual test modes – Lenze i700 User Manual

Page 61: 0x2835, 0x3035, 5motor control & motor settings

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

61

5

Motor control & motor settings

5.3

Wiring check by means of manual test modes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.3

Wiring check by means of manual test modes

Before the parameterisation of the actual control is started, the wiring of the motor (power and

encoder connection) should be checked for errors and, if required, should be corrected.

• For this purpose, the following manual test modes can be activated via object

0x2825

(or

0x3025

for axis B) when the controller is inhibited:

Manual test mode "voltage/frequency"

Manual test mode "current/frequency"

• The parameters for the test modes can be adapted via object

0x2835

(or

0x3035

for axis B). For

this, observe the notes in the description of the respective test mode.

0x2835 | 0x3035 - Manual test mode: Settings

Sub.

Name

Lenze setting

Data type

1

Manual test mode: Current setpoint

0 %

INTEGER_16

2

Manual test mode: Frequency

0.0 Hz

INTEGER_16

3

Manual test mode: Starting angle

0.0 °

INTEGER_16

Subindex 1:

Manual test mode: Setpoint current

Selection of the r.m.s. value of a phase current for test mode

• 100 % ≡ rated motor current (

0x6075

or

0x6875

for axis B)

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

1000 0 %

Write access  CINH  OSC  P  RX  TX

INTEGER_16

Subindex 2:

Manual test mode: Frequency

Selection of the frequency for test mode
Setting range

(min. value | unit | max. value)

Lenze setting

-1000.0

Hz

1000.0 0.0 Hz

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Subindex 3:

Manual test mode: Starting angle

Selection of the starting angle for test mode

Note!

In the case of the synchronous motor, a jerky compensating movement occurs after controller enable if the pole

position of this movement does not correspond to the starting angle.
Setting range

(min. value | unit | max. value)

Lenze setting

-1000.0

°

1000.0 0.0 °

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Advertising