Parameter handling

2.1

Parameter transfer during initialisation

18

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2

Parameter handling

2.1

Parameter transfer during initialisation

During the acceleration of the system, the controller and the controllers exchange configuration

data (e.g. bus cycle and PDO mapping). With regard to this, observe the following particular features

for the i700 servo inverter:

Parameter download
The i700 servo inverter itself does not store parameter settings safe against mains failure. All

settings deviating from the i700 servo inverter "Lenze setting" (default) are maintained centrally in

the controller and are stored there permanently (persistently). During the initialisation at run-up,

only these deviations are transferred to the i700 servo inverter by the controller. Like this it is

ensured that the i700 servo inverter works with the parameter settings provided for it.

Firmware download (optional)
If required, the firmware of the i700 servo inverter can be stored together with the »PLC Designer«

project. During the run-up, the controller then checks whether the firmware version in the i700

servo inverter complies with the firmware version stored in the project for this device. If this is not

the case, the controller loads the firmware version stored in the project to the i700 servo inverter.

Like this, it can be ensured for "Device replacement" service work that the replacement device also

works with the same firmware version as the original device.