1 manual test mode "voltage/frequency, Manual test mode "voltage/frequency, Test mode "voltage/frequency – Lenze i700 User Manual

Page 62: 5motor control & motor settings

Advertising
background image

5

Motor control & motor settings

5.3

Wiring check by means of manual test modes

62

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.3.1

Manual test mode "voltage/frequency"

Functional description
In this test mode, a rotating field voltage with the set output frequency f

out

is output at the motor

terminals after controller enable.

• If the frequency selection is positive, the motor should rotate clockwise when one is looking at

the A-side of the motor. If this is not the case, there is a simple rotating movement in the motor

phases.

• The level of the output voltage is determined via the following equation:

By means of the manual "Voltage/frequency" test mode, the wiring of the feedback system can also

be checked.

• If the feedback system is set correctly, the following actual speed should be shown:

Equation for calculating the output voltage

Axis A

Axis B

Symbol Description

Dimension unit

0x2D82

0x3582

V

out

Current output voltage

V

0x2835:2 0x3035:2

f

out

Output frequency for test mode

Hz

0x2B01:1 0x3301:1

V

rated

V/f rated voltage

V

0x2B01:2 0x3301:2

f

rated

V/f base frequency

Hz

Greyed out = read access only

Equation for calculating the actual speed

Axis A

Axis B

Symbol Description

Dimension unit

0x606C

0x686C

n

act

Velocity actual value

rpm

0x2835:3 0x3035:3

f

out

Output frequency for test mode

Hz

0x2C01:1 0x3401:1

zp

Motor

Motor - number of pole pairs

Greyed out = read access only

U

out

f

out

U

rated

f

rated

---------------

=

n

act

f

out

zp

motor

-------------------

60

=