Field weakening operation - synchronous motor (sm), 5motor control & motor settings, Stop – Lenze i700 User Manual

Page 121

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

121

5

Motor control & motor settings

5.11

Setting control loops

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.11.7

Field weakening operation - synchronous motor (SM)

The control of the i700 servo inverter permits the operation of a synchronous motor outside the

voltage range. If a motor is selected in the »Easy Starter«, the control is automatically

parameterised.
In order to improve the transition from the base speed range to field weakening, we recommend the

activation of the current controller feedforward control via the object

0x2941

(or

0x3141

for axis B).

• The current controller feedforward control is determined via the following parameters:

• Motor stator resistance (

0x2C01:2

or

0x3401:2

for axis B)

• Motor stator leakage inductance (

0x2C01:3

or

0x3401:3

for axis B)

• e.m.f constant (

0x2C03:1

or

0x3403:1

for axis B)

• If a third-party motor is to be operated in the field weakening range, the parameters mentioned

before have to be selected carefully.

The terminal voltage approximately corresponds to the following equation:

Stop!

Operation of synchronous motors outside the voltage range:
If a pulse inhibit is set in the controller, e.g. in the case of a controller inhibit or in the

event of an error, the DC bus will load up to the terminal voltage corresponding to the

actual speed (see equation below).

• At high speeds outside the voltage range, the terminal voltage may be higher than the

mains voltage!

• Connect a brake chopper to the DC bus to prevent the DC bus from reaching

impermissibly high voltages!

Equations for calculating the terminal voltage

Axis A

Axis B

Description

Dimension unit

0x2540:1

Rated mains voltage

V

0x2C01:4 0x3401:4

Rated motor speed

r/min

V

Terminal

Actual speed Rated mains voltage

Rated motor speed

-----------------------------------------------------

=