0x2d50, 0x3550, An error response in the object – Lenze i700 User Manual

Page 242: 0x2d50:1, 0x3550:1, 8monitoring functions

Advertising
background image

8

Monitoring functions

8.4

Monitoring of the motor utilisation (I²xt)

242

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2D50 | 0x3550 - motor utilisation (I²xt): Motor overload error

The introduction of a two-component model with two time constants (one for the winding and the

housing/laminated core, respectively) serves to display the thermal behaviour of the motors up to

500% of the rated current.

From version 01.04 onwards

If the disconnection must not or cannot be executed by a higher-level Controller, the operation can be interrupted

by the following parameter setting:

• As a response to the excess of the adjustable error threshold, set "1: Fault" in subindex 1.

• In subindex 2, set the threshold value as error threshold which in case of being exceeded triggers an interruption

of the operation.

Sub.

Name

Lenze setting

Data type

1

Motor utilisation (I²xt): Response

0: No Response

UNSIGNED_8

2

Motor utilisation (I²xt): Error threshold

105 %

UNSIGNED_16

Subindex 1:

Motor utilisation (I²xt): Response

Selection list

(Lenze setting printed in bold)

0 No response
1 Fault

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Subindex 2:

Motor utilisation (I²xt): Error threshold

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

250 105 %

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

Structure of the I

2

xt monitoring

Thermal utilisation of the motor in [%]

Axis A

Axis B

Symbol Description

Dimension unit

-

-

I

act motor

Actual motor current

A

-

-

I

perm motor

Permissible motor current (speed-dependent)

A

0x2D4C:1 0x354C:1

τ

1

Therm. time constant coil

s

0x2D4C:2 0x354C:2

τ

2

Therm. time constant of the laminated core

s

0x2D4C:3 0x354C:3

k

1

Percentage of the winding in the final temperature

%

-

-

k

2

Percentage of the laminated core in the final temperature:

k

2

= 100 % - k

1

%

k

1

1

(1 + p

)

t

1

k

2

1

(1 + p

)

t

2

Œ

I

act motor

I

perm motor

(n)

2

Advertising