2 device states, Device states, Device – Lenze i700 User Manual

Page 179: States, 7cia402 device profile

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

179

7

CiA402 device profile

7.4

Device control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.2

Device states

The current device status of the drive can be read via the Statusword

(

0x6041

or

0x6841

for axis B):

Tip!
Bits 4 ("Voltage enabled") and 7 ("Warning active") are not relevant as regards the device

status and merely serve the purpose of a better readability of the bit patterns here.
Detailed information on the different device states can be obtained from the following

subchapters.

"Warning active" status bit
Via bit 7 in the Statusword, a warning is indicated.

• The occurrence of a warning does not cause a state change.
• Warnings do not need to be reset.

Device status

Bit pattern in the Statusword

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Warning is

active

Switch on

disabled

Quick stop

Voltage

enabled

Fault active

Operation

enabled

Switched on

Ready to

switch on

Not ready to switch

on

X

0

X

X

0

0

0

0

Switch on disabled

X

1

X

X

0

0

0

0

Ready to switch on

X

0

1

X

0

0

0

1

Switched on

X

0

1

X

0

0

1

1

Operation enabled

X

0

1

X

0

1

1

1

Quick stop is active

X

0

0

X

0

1

1

1

Fault reaction active

X

0

X

X

1

1

1

1

Fault

X

0

X

X

1

0

0

0

X = Status not significant