5.14

Parameterising the V/f characteristic control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2B02 | 0x3302 - VFC: User-definable V/f characteristic - frequency grid points (x)

0x2B03 | 0x3303 - VFC: User-definable V/f characteristic - voltage grid points (y)

Sub.

Name

Lenze setting

Data type

1 V/f: x1 = f01

-50 Hz

INTEGER_16

2 V/f: x2 = f02

-40 Hz

INTEGER_16

3 V/f: x3 = f03

-30 Hz

INTEGER_16

4 V/f: x4 = f04

-20 Hz

INTEGER_16

5 V/f: x5 = f05

-10 Hz

INTEGER_16

6 V/f: x6 = f06

0 Hz

INTEGER_16

7 V/f: x7 = f07

10 Hz

INTEGER_16

8 V/f: x8 = f08

20 Hz

INTEGER_16

9 V/f: x9 = f09

30 Hz

INTEGER_16

10 V/f: x10 = f10

40 Hz

INTEGER_16

11 V/f: x11 = f11

50 Hz

INTEGER_16

Write access  CINH  OSC  P  RX  TX

Sub.

Name

Lenze setting

Data type

1 V/f: y1 = U01 (x = f01)

400.00 V

UNSIGNED_32

2 V/f: y2 = U02 (x = f02)

320.00 V

UNSIGNED_32

3 V/f: y3 = U03 (x = f03)

240.00 V

UNSIGNED_32

4 V/f: y4 = U04 (x = f04)

160.00 V

UNSIGNED_32

5 V/f: y5 = U05 (x = f05)

80.00 V

UNSIGNED_32

6 V/f: y6 = U06 (x = f06)

0.00 V

UNSIGNED_32

7 V/f: y7 = U07 (x = f07)

80.00 V

UNSIGNED_32

8 V/f: y8 = U08 (x = f08)

160.00 V

UNSIGNED_32

9 V/f: y9 = U09 (x = f09)

240.00 V

UNSIGNED_32

10 V/f: y10 = U10 (x = f10)

320.00 V

UNSIGNED_32

11 V/f: y11 = U11 (x = f11)

400.00 V

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX