Motor control & motor settings

5.14

Parameterising the V/f characteristic control

138

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2B01 | 0x3301 - VFC: V/f characteristic - define reference point

Defining a user-defined V/f characteristic
The "User-definable V/f characteristic" is provided for the individual adjustment of the motor

magnetisation to the actual application if linear and square-law characteristics are not suitable.

• The characteristic is defined by means of 11 parameterisable grid points (voltage/frequency

values).

• In the Lenze setting the 11 grid points represent a linear characteristic:

[5-10] User-definable V/f characteristic (Lenze setting)

Sub.

Name

Lenze setting

Data type

1

VFC: V/f characteristic - voltage at reference

point

225 V

UNSIGNED_16

2

VFC: V/f characteristic - frequency at reference

point

270 Hz

UNSIGNED_16

Subindex 1:

VFC: V/f characteristic - voltage at reference point

Setting range

(min. value | unit | max. value)

Lenze setting

0

V

5000 225 V

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

Subindex 2:

VFC: V/f characteristic - frequency at reference point

Setting range

(min. value | unit | max. value)

Lenze setting

0

Hz

5000 270 Hz

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

P1

P2

P3

P4

P5

P6

P7

P8

P9

P10

P11

V

400 V

320 V

240 V

160 V

80 V

0 V

80 V

160 V

240 V

320 V

400 V

f

-50 Hz

-40 Hz

-30 Hz

-20 Hz

-10 Hz

0 Hz

10 Hz

20 Hz

30 Hz

40 Hz

50 Hz

0x2B02:11 | 0x3302:11
0x2B03:11 | 0x3303:11

U [V]

160

0

f [Hz]

240

320

400

10

20

30

40

50

-50

-40

-30

-20

-10

80

0x2B02:1 | 0x3302:1
0x2B03:1 | 0x3303:1

P1

P2

P3

P4

P5

P7

P6

P8

P9

P10

P11

Advertising