6 holding brake control, 1 operating modes, Holding brake control – Lenze i700 User Manual

Page 157: Operating modes, Holding brake, Control, 6holding brake control

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

157

6

Holding brake control

6.1

Operating modes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6

Holding brake control

This device function is used to control a motor holding brake connected to the i700 servo inverter.

Objects described in this chapter

6.1

Operating modes

For holding brake control, the following three operating modes available for the i700 servo inverter

in the object

0x2820:1

(or

0x3020:1

for axis B):

• Triggering via control word via external control (Lenze setting)
• Triggering via state machine of device
• No brake connected

Tip!
We recommend the use of the preset "Triggering via control word from external control"

mode. In this operating mode, the triggering is carried out via the application program in

the Controller.

You can find detailed information on the respective operating mode in the following subchapters.

Note!

In the "

Fault

" device status, the holding brake is applied.

Object

Name

Data type

Axis A

Axis B

0x2820

0x3020

Brake control: Settings

RECORD

Advertising