CiA402 device profile

7.8

Cyclic sync position mode (csp)

208

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Tip!
A detailed representation of the signal flow with all relevant parameters can be found in

the »PLC Designer« on the Signal flow tab for the i700 servo inverter.

7.8.4

Control commands & status information

The following control commands can be executed in cyclic sync position mode via the Controlword

(

0x6040

or

0x6840

for axis B):

The following status information is output in cyclic sync position mode via the Statusword (

0x6041

or

0x6841

for axis B):

Field-oriented control

0x6073

0x6873

Max current

0x6075

0x6875

Motor rated current

0x2941

0x3141

Current controller: Feedforward control

0x2942:1 0x3142:1

Current controller: Gain

0x2942:2 0x3142:2

Current controller: Reset time

0x29E2

0x31E2

DC link circuit voltage: Filter time

0x29E3

0x31E3

Motor voltage act. value: Filter time

0x29E0:1 0x31E0:1

Field weakening controller: Gain

0x29E0:2 0x31E0:2

Field weakening controller: Reset time

0x29E1

0x31E1

Field set value limitation

0x29C0:1 0x31C0:1

Field controller: Gain

0x29C0:2 0x31C0:2

Field controller: Reset time

0x2939

0x3139

Switching frequency

Function

Object

Name

Axis A

Axis B

,

T

,

G

Control word

Status Function

Bit 4

0 Reserved (bit must be set to "0")

Bit 5

0 Reserved (bit must be set to "0")

Bit 6

0 Reserved (bit must be set to "0")

Bit 8

0  1 Stop

Status word

Status Meaning

Bit 12

0 Cyclic sync position mode inactive
1 Cyclic sync position mode active