0x2dd1 | 0x35d1 - motor: currents, 0x2dd1:1, 0x35d1:1 – Lenze i700 User Manual
Page 284: Rrent, 0x2dd1:3, 0x35d1:3, 0x2dd1:5, 0x35d1:5, 0x2dd1, 0x35d1
10
Service/internal
284
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2DD1 | 0x35D1 - motor: Currents
0x2DD2 | 0x35D2 - Position: Target position interpolated
Sub.
Name
Lenze setting
Data type
D-current (id): Actual D-current
INTEGER_16
Q-current (iq): Actual Q-current
INTEGER_16
D-current (id): D-current setpoint
INTEGER_16
Q-current (iq): Q-current setpoint
INTEGER_16
Motor current Ieff
INTEGER_16
Subindex 1:
D current (id): Actual D-current
Display area
(min. value | unit | max. value)
Initialisation
-327.67
A
327.67
Write access CINH OSC P RX TX
Scaling: 1/100
INTEGER_16
Subindex 2:
Q current (iq): Actual Q-current
Display area
(min. value | unit | max. value)
Initialisation
-327.67
A
327.67
Write access CINH OSC P RX TX
Scaling: 1/100
INTEGER_16
Subindex 3:
D current (id): Target D current
Display area
(min. value | unit | max. value)
Initialisation
-327.67
A
327.67
Write access CINH OSC P RX TX
Scaling: 1/100
INTEGER_16
Subindex 4:
Q current (iq): Target Q current
Display area
(min. value | unit | max. value)
Initialisation
-327.67
A
327.67
Write access CINH OSC P RX TX
Scaling: 1/100
INTEGER_16
Subindex 5:
Motor current Ieff
Note!
The r.m.s. value of the current is calculated from the time values by means of the use of the factor "√2". This also
happens in case of the field frequency 0 Hz (DC current). In case of the DC injection braking, the r.m.s. value is thus
given in this object by the factor "√2" too low.
Display area
(min. value | unit | max. value)
Initialisation
-327.67
A
327.67
Write access CINH OSC P RX TX
Scaling: 1/100
INTEGER_16
Display area
(min. value | unit | max. value)
Initialisation
-2147483647
[Pos unit]
2147483647 0 [Pos unit]
Write access CINH OSC P RX TX
INTEGER_32