0x2c03 | 0x3403 - motor (sm): parameter, 0x6075 | 0x6875 - motor rated current, 0x2c03 – Lenze i700 User Manual

Page 83: 0x3403, 0x6075, 0x6875, For axi, In object, For ax, 0x2c03:1 0x3403:1

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

83

5

Motor control & motor settings

5.8

Setting the motor parameters for the servo control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2C03 | 0x3403 - Motor (SM): Parameter

0x6075 | 0x6875 - Motor rated current

Sub.

Name

Lenze setting

Data type

1

Motor (SM): e.m.f. constant (KELL)

41.8 V/1000 rpm

UNSIGNED_32

2

Motor (SM): Pole position resolver

-90.0 °

INTEGER_16

3

Motor (SM): Temperature coefficient -

magnets (kTN)

-0.110 %/°C

INTEGER_16

4

Motor (SM): Pole position encoder

0.0 °

INTEGER_16

Subindex 1:

Motor (SM): e.m.f. constant (KELL)

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

V/1000 rpm

100000.0 41.8 V/1000 rpm

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

UNSIGNED_32

Subindex 2:

Motor (SM): Pole position resolver

Setting range

(min. value | unit | max. value)

Lenze setting

-179.9

°

179.9 -90.0 °

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Subindex 3:

Motor (SM): Temperature coefficient - magnets (kTN)

Setting range

(min. value | unit | max. value)

Lenze setting

-1.000

%/°C

0.000 -0.110 %/°C

Write access  CINH  OSC  P  RX  TX

Scaling: 1/1000

INTEGER_16

Subindex 4:

Motor (SM): Pole position encoder

From version 01.03

Setting range

(min. value | unit | max. value)

Lenze setting

-179.9

°

179.9 0.0 °

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

The rated motor current set here serves as a reference value for the following objects:

• 0x6073 | 0x6873 - Device: Max. current

• 0x6078 | 0x6878 - Current actual value

• 0x2835 | 0x3035 - Manual test mode: Settings

• 0x2C61 | 0x3461 - Pole position identification PPI (360°)

• 0x2C62 | 0x3462 - Pole position identification PPI (min. movement)

• 0x2D4D | 0x354D - Motor utilisation (I²xt): User-definable characteristic

Setting range

(min. value | unit | max. value)

Lenze setting

0.001

A

500.000 1.300 A

Write access  CINH  OSC  P  RX  TX

Scaling: 1/1000

UNSIGNED_32