0x608f | 0x688f - position encoder resolution, 0x6090 | 0x6890 - velocity encoder resolution, 0x608f – Lenze i700 User Manual

Page 191: 0x688f, 0x6090, 0x6890, Lution, 7cia402 device profile

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

191

7

CiA402 device profile

7.5

Parameters for the scaling of physical values

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x608F | 0x688F - Position encoder resolution

0x6090 | 0x6890 - Velocity encoder resolution

Resolution of the position detection by the motor encoder

Sub.

Name

Lenze setting

Data type

1

Encoder increments

0x00010000: 16 Bit

UNSIGNED_32

2

Motor revolutions

1

UNSIGNED_32

Subindex 1:

Encoder increments

Setting of the number of bits with which a mechanical motor revolution is to be resolved.
Selection list

(Lenze setting printed in bold)

0x00010000 16 bits
0x00040000 18 bits
0x00100000 20 bits
0x00400000 22 bits
0x01000000 24 bits
0x04000000 26 bits
0x10000000 28 bits
0x40000000 30 bits

Write access  CINH  OSC  P  RX  TX

UNSIGNED_32

Subindex 2:

Motor revolutions

Number of motor revolutions

• Only the setting "1" is accepted.

Setting range

(min. value | unit | max. value)

Lenze setting

1

1 1

Write access  CINH  OSC  P  RX  TX

UNSIGNED_32

Note: This object is not used in the firmware and only available for compatibility reasons. Do not use the contained

values for a calculation on the control level.

Sub.

Name

Lenze setting

Data type

1 Incr./s

33554432

UNSIGNED_32

2 Motor revolutions/s

125

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX