0x6049 | 0x6849 - vl velocity deceleration, 3 signal flow (servo control), Signal flow (servo control) – Lenze i700 User Manual

Page 198: 0x6049, 0x6849, 7cia402 device profile, Ctrl

Advertising
background image

7

CiA402 device profile

7.7

Velocity mode (vl)

198

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x6049 | 0x6849 - vl velocity deceleration

7.7.3

Signal flow (servo control)

[7-2]

Signal flow of the servo control in "Velocity mode" (simplified representation)

Short overview of the most important parameters:

Sub.

Name

Lenze setting

Data type

1

Delta speed

0 rpm

UNSIGNED_32

2

Delta time

10 s

UNSIGNED_16

Subindex 1:

Delta speed

Setting range

(min. value | unit | max. value)

Lenze setting

0

r/min

2147483647 0 rpm

Write access  CINH  OSC  P  RX  TX

UNSIGNED_32

Subindex 2:

Delta time

Setting range

(min. value | unit | max. value)

Lenze setting

0

s

65535 10 s

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

I

q

I

d

M

CTRL

vl target velocity

Torque offset

Controlword

Lenze control word

Modes of operation

Speed

limitation

Speed

controller

Ramp

function

Statusword

Lenze status word

Modes of operation display

Positive torque limit value

Negative torque limit value

Interpolation

Torque
limitation

Encoder

evaluation

Field-orientated
control

vl velocity actual value

Torque actual value

vl velocity
demand

Position actual value

Function

Object

Name

Axis A

Axis B

Input data

0x6040

0x6840

Controlword

0x2830

0x3030

Lenze control word

0x6060

0x6860

Operating mode: Selection

0x6042

0x6842

vl target velocity

0x60B2

0x68B2

Torque offset

0x60E0

0x68E0

Positive torque limit value

0x60E1

0x68E1

Negative torque limit value

Advertising