2 object description, 0x6042 | 0x6842 - vl target velocity, 0x6043 | 0x6843 - vl velocity demand – Lenze i700 User Manual

Page 196: Object description, 0x6042, 0x6842, 0x6043, 0x6843, 7cia402 device profile

Advertising
background image

7

CiA402 device profile

7.7

Velocity mode (vl)

196

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.7.2

Object description

The following two tables provide an overview of the most important objects for this operating

mode (without motor parameters, motor control parameters, and feedback parameters).
All objects correspond to the CiA402 specification, but some of them have only a restricted value

range.

Objects described in other chapters:

Objects described in this chapter:

0x6042 | 0x6842 - vl target velocity

0x6043 | 0x6843 - vl velocity demand

Object

Name

Data type

Axis A

Axis B

Lenze control and status word

0x2830

0x3030

Lenze control word

UNSIGNED_16

0x2831

0x3031

Lenze status word

UNSIGNED_16

Device control

0x6040

0x6840

Controlword

UNSIGNED_16

0x6060

0x6860

Operating mode: Selection

INTEGER_8

0x6041

0x6841

Statusword

UNSIGNED_16

0x6061

0x6861

Modes of operation display

INTEGER_8

Greyed out = read access only

Object

Name

Data type

Axis A

Axis B

0x6042

0x6842

vl target velocity

INTEGER_16

0x6043

0x6843

vl velocity demand

INTEGER_16

0x6044

0x6844

vl velocity actual value

INTEGER_16

0x6046

0x6846

vl velocity min max amount

RECORD

0x6048

0x6848

vl velocity acceleration

RECORD

0x6049

0x6849

vl velocity deceleration

RECORD

Setting range

(min. value | unit | max. value)

Lenze setting

-32768

r/min

32767 0 rpm

Write access  CINH  OSC  P  RX  TX

INTEGER_16

Display area

(min. value | unit | max. value)

Initialisation

-32768

r/min

32767

Write access  CINH  OSC  P  RX  TX

INTEGER_16

Advertising