5motor control & motor settings – Lenze i700 User Manual

Page 79

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

79

5

Motor control & motor settings

5.8

Setting the motor parameters for the servo control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

After the parameters have been extracted from the impedance, they are checked for consistency

with the required rated values. If an inconsistent parameter set is detected, is this an indication of

faulty rated values on the nameplate.

Preconditions for the execution

• The synchronous motor must be able to rotate freely.
• The asynchronous motor may be firmly braked.
• The controller is free of errors and is in the "

Switched on

" device status.

• The motor parameters listed in the following table are excluded from the automatic

determination and must therefore be adapted to the motor used (see motor nameplate before

the determination.

Response of the motor during the execution

• A DC current is superimposed over the identification current that keeps the motor idling. After

the controller enable, the shaft will adjust once, which is irrelevant to measurement though.

• With asynchronous motors, slight rotations might possibly occur. Their influence on the

measurements is, however, not worth mentioning.

Object

Name

Axis A

Axis B

0x6075

0x6875

Motor rated current

(The current amount for the procedure is derived from this specification)

0x2C01:2 0x3401:2

Motor: Stator resistance

(Default setting is used as starting value for the automatic determination.)

0x2C01:4 0x3401:4

Motor: Rated speed

0x2C01:5 0x3401:5

Motor: Rated frequency

0x2C01:6 0x3401:6

Motor: Rated power

0x2C01:7 0x3401:7

Motor: Rated voltage

Note!

• In case of uncertainties, the measurement should be repeated several times to check

if the results for the stator resistance, the leakage inductance of the stator and the

rotor resistance differ widely. This should not be the case.

• The mutual inductance and the cos(ϕ) values are not that important for the

diagnostics, because they are strongly non-linear.