Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

123

5

Motor control & motor settings

5.12

Fine adjustment des motor model

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Distribution of the grid points

• The saturation characteristic is represented by means of 17 grid points.
• The 17 grid points are spaced on the X axis at equal intervals (equidistantly) in a range of

0 ... 100 %. The 100% value of the X axis refers to the current value (max. motor current in the

process) set in object

0x2C05

(or

0x3405

for axis B).

• The Y values for the grid points can be accessed via the subindices of object

0x2C04

(or

0x3404

for axis B).

[5-2]

Saturation characteristic: Distribution of the grid points

• The 100 % value of a grid point refers to

• the set motor stator leakage inductance (

0x2C01:3

or

0x3401:3

for axis B)

and

• the set current controller gain Vp (

0x2942:1

or

0x3142:1

for axis B).

• Preferably select a display area of the grid points which includes at least the ultimate motor

current. The current controller step response is then recorded actively only until the grid point

with peak motor current. In order to prevent the motor winding from being overloaded, the

manual test mode "current pulse" should be used for recording. The grid points with current

setpoints above the peak motor current are determined through interpolation.

• When the saturation characteristics for motor types are determined, it makes sense in some

cases to select a scaled representation of the grid point distribution. This requires to know the

highest value of the quotient from "ultimate motor current / rated motor current" of the motor

series.

Note!

The saturation characteristic is not only used to correct the current controller, but it also

influences the current controller feedforward control (can be activated via object

0x2941

or

0x3141

for axis B).

0

6.25

12.5

18.75

25

31.25

37.5

43.75

50

56.25

62.5

68.75

75

81.25

87.5

93.75

100

I

max

Vp
Tn

[V/A]

[ms]

[%]

x2

x3

x4

x5

x6

x7

x8

x9

x10

x11

x12

x13

x14

x15

x16

x17

x1