11 appendix, 1 table of attributes 296 – Lenze i700 User Manual

Page 296

Advertising
background image

11

Appendix

11.1

Table of attributes

296

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2C45

Open circuit in feedback system: Response

UNSIGNED_8

-

P

0x2C46

Feedback system: Specifiable number of revolutions

UNSIGNED_16

-

0x2C5F

Feedback system: Parameter CRC

UNSIGNED_32

-

Axis A - pole position identification

0x2C60

Monitoring pole position identification: Response

UNSIGNED_8

-

P

0x2C61

Pole position identification PPI (360°)
1: PPI (360°): Current amplitude

UNSIGNED_16

-

P

CINH

2: PPI (360°): Ramp time

UNSIGNED_16

-

P

CINH

3: PPI (360°): Direction of rotation

UNSIGNED_8

-

P

CINH

4: PPI (360°): Fault tolerance

UNSIGNED_8

-

P

5: PPI (360°): Absolute current amplitude

UNSIGNED_32

1/100

0x2C62

Pole position identification PPI (min. movement)
1: PPI (min. movement): Current amplitude

UNSIGNED_16

-

P

CINH

2: PPI (min. movement): Ramp time - current

UNSIGNED_16

-

P

CINH

3: PPI (min. movement): Gain

UNSIGNED_16

-

P

4: PPI (min. movement): Reset time

UNSIGNED_16

1/10

P

5: PPI (min. movement): Max. move permitted

UNSIGNED_8

-

P

6: PPI (min. movement): Absolute current amplitude

UNSIGNED_32

1/100

0x2C63

Pole position identification PPI (without movement)
1: Behaviour after switch-on

UNSIGNED_8

-

P

CINH

Axis A - touch probe

0x2D00

Touch probe (TP): Dead time compensation
1: Dead time compensation: TP1 delay time

UNSIGNED_16

1/1000

P

2: Dead time compensation: TP2 delay time

UNSIGNED_16

1/1000

P

0x2D01

Touch probe (TP): Time stamp
1: TP1: Time stamp - rising edge

UNSIGNED_32

-

OSC

Tx

2: TP1: Time stamp - falling edge

UNSIGNED_32

-

OSC

Tx

3: TP2: Time stamp - rising edge

UNSIGNED_32

-

OSC

Tx

4: TP2: Time stamp - falling edge

UNSIGNED_32

-

OSC

Tx

Axis A - monitoring functions

0x2D40

Ixt utilisation
1: Power stage utilisation (Ixt): Actual utilisation

UNSIGNED_16

-

OSC

Tx

2: Power stage utilisation (Ixt): Warning threshold

UNSIGNED_16

-

P

3: Power stage utilisation (Ixt): Error threshold

UNSIGNED_16

-

4: Device utilisation (Ixt): Actual utilisation

UNSIGNED_16

-

OSC

Tx

5: Device utilisation (Ixt): Warning threshold

UNSIGNED_16

-

P

6: Device utilisation (Ixt): Error limit

UNSIGNED_16

-

0x2D44

Motor speed monitoring
1: Motor speed monitoring: Threshold

UNSIGNED_16

-

P

2: Motor speed monitoring: Response

UNSIGNED_8

-

P

0x2D45

Motor phase failure detection
1: Motor phase failure 1: Response

UNSIGNED_8

-

P

2: Motor phase failure 1: Current threshold

UNSIGNED_8

1/10

P

3: Motor phase failure 1: Voltage threshold

UNSIGNED_16

1/10

P

4: Motor phase failure 2: Response

UNSIGNED_8

-

P

0x2D46

Monitoring: Ultimate motor current
1: Ultimate motor current: Threshold

UNSIGNED_16

1/10

P

2: Ultimate motor current: Response

UNSIGNED_8

-

P

Index

Name

Data type

Scaling

Attributes

Greyed out = read only

Advertising