0x2d4c, 0x354c, 0x2d4c:1 0x354c:1 – Lenze i700 User Manual

Page 243: 0x2d4c:2 0x354c:2, 0x2d4c:3 0x354c:3, 8monitoring functions

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

243

8

Monitoring functions

8.4

Monitoring of the motor utilisation (I²xt)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2D4C | 0x354C - Motor utilisation (I²xt): Parameter for the thermal model

Calculation with only one time constant
If k1 = "0 %" is set, the part of the winding is not taken into consideration and the thermal model is

only calculated using the time constant set for the housing/laminated core. This setting is e.g.

required if only the time constant of the laminated core (T2) is known.

Sub.

Name

Lenze setting

Data type

1

Motor utilisation (I²xt): Thermal time constant

- winding

60 s

UNSIGNED_16

2

Motor utilisation (I²xt): Thermal time constant

- laminations

852 s

UNSIGNED_16

3

Motor utilisation (I²xt): Influence of the

winding

27 %

UNSIGNED_8

4

Motor utilisation (I²xt): Starting value

0 %

UNSIGNED_16

Subindex 1:

Motor utilisation (I²xt): Thermal time constant of the winding

Setting range

(min. value | unit | max. value)

Lenze setting

1

s

36000 60 s

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

Subindex 2:

Motor utilisation (I²xt): Thermal time constant - laminated core

Setting range

(min. value | unit | max. value)

Lenze setting

1

s

36000 852 s

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

Subindex 3:

Motor utilisation (I²xt): Influence of the winding

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 27 %

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Subindex 4:

Motor utilisation (I²xt): Starting value

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

250 0 %

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

Advertising