0x2c07, 0x3407, Load standard lh saturation characteristic – Lenze i700 User Manual

Page 130: 5motor control & motor settings

Advertising
background image

5

Motor control & motor settings

5.12

Fine adjustment des motor model

130

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Loading the standard Lh saturation characteristic
If an incorrect Lh saturation characteristic has been determined or none at all, it is possible to load

a device-typical standard Lh characteristic.

How to load the standard Lh saturation characteristic:

1. Set object

0x2822

(or

0x3022

for axis B) to "13".

• The progress of the procedure is shown in object

0x2823

(or

0x3023

for axis B).

2. For permanent storage: After completion of the procedure, upload the Lh saturation

characteristic set in

0x2C07

(or

0x3407

for axis B) to the controller from the i700 servo

inverter.
The »EASY Starter« serves to save the parameter settings of the i700 servo inverter as

parameter file (*.gdc). In the »PLC Designer«, this file can then be imported in the

corresponding axis.

Saving changed parameters safe against mains failure

( 60)

0x2C07 | 0x3407 - Motor (ASM): Lh saturation characteristic - inductance grid points (y)

Sub.

Name

Lenze setting

Data type

1 Lh: y1 = L01 (x = 0.00 %)

118 %

UNSIGNED_16

2 Lh: y2 = L02 (x = 6.25 %)

118 %

UNSIGNED_16

3 Lh: y3 = L03 (x = 12.50 %)

118 %

UNSIGNED_16

4 Lh: y4 = L04 (x = 18.75 %)

117 %

UNSIGNED_16

5 Lh: y5 = L05 (x = 25.00 %)

116 %

UNSIGNED_16

6 Lh: y6 = L06 (x = 31.25 %)

114 %

UNSIGNED_16

7 Lh: y7 = L07 (x = 37.50 %)

111 %

UNSIGNED_16

8 Lh: y8 = L08 (x = 43.75 %)

107 %

UNSIGNED_16

9 Lh: y9 = L09 (x = 50.00 %)

100 %

UNSIGNED_16

10 Lh: y10 = L10 (x = 56.25 %)

93 %

UNSIGNED_16

11 Lh: y11 = L11 (x = 62.50 %)

86 %

UNSIGNED_16

12 Lh: y12 = L12 (x = 68.75 %)

78 %

UNSIGNED_16

13 Lh: y13 = L13 (x = 75.00 %)

71 %

UNSIGNED_16

14 Lh: y14 = L14 (x = 81.25 %)

64 %

UNSIGNED_16

15 Lh: y15 = L15 (x = 87.50 %)

57 %

UNSIGNED_16

16 Lh: y16 = L16 (x = 93.75 %)

50 %

UNSIGNED_16

17 Lh: y17 = L17 (x = 100.00 %)

42 %

UNSIGNED_16

Write access  CINH  OSC  P  RX  TX