0x2833 | 0x3033 - lenze statusword 2, 0x2833, 0x3033 – Lenze i700 User Manual

Page 30: 3communication with the controller

Advertising
background image

3

Communication with the controller

3.5

Lenze control and status word

30

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2833 | 0x3033 - Lenze statusword 2

From version 01.03

Display area

(min. value | unit | max. value)

Initialisation

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Feedback modification

Changes in the settings of the feedback system have

been executed. The status bit is reset at controller

enable.

Bit 1 Manual test mode active

A manual test mode is active

(

0x2825

or

0x3025

= 1, 2 or 3)

Bit 2 Manual control mode active

Manual control mode is active

(

0x2825

or

0x3025

= 4)

Bit 3 Angle tracking control: Active

Reserved

Bit 4 Absolute value encoder selected

From version 01.06

Absolute feedback system selected (parameterised)

• In case of the "resolver" device variant, this bit is set if

the resolver pole pair number "1" is set in

0x2C43

(or

0x3443

for axis B).

• In case of the "encoder" device variant, this bit is set if

the encoder type "2: Hiperface absolute value

encoder" is set in

0x2C40

(or

0x3440

for axis B).

Bit 5 Absolut position available

From version 01.06

Initialisation of the selected feedback system is

completed. All information of the feedback system have

been transmitted.

• In case of an error in the feedback system, this bit is

set to "0" as long as the error exists.

Bit 6 DC-injection braking or short-circuit

braking: Active

From version 01.06

DC-injection braking for asynchronous motor or short-

circuit braking for synchronous motor is active

Bit 7-15 Reserved

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16