6 motor speed monitoring, 0x2d44 | 0x3544 - motor speed monitoring, Motor speed monitoring – Lenze i700 User Manual

Page 253: 0x2d44:1 0x3544:1, 0x2d44, 0x3544, 8monitoring functions

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

253

8

Monitoring functions

8.6

Motor speed monitoring

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.6

Motor speed monitoring

0x2D44 | 0x3544 - Motor speed monitoring

Sub.

Name

Lenze setting

Data type

1

Motor speed monitoring: Threshold

8000 r/min

UNSIGNED_16

2

Motor speed monitoring: Response

1: Trouble

UNSIGNED_8

Subindex 1:

Motor speed monitoring: Threshold

Warning/error threshold for motor speed monitoring
Setting range

(min. value | unit | max. value)

Lenze setting

50

r/min

50000 8000 r/min

Write access  CINH  OSC  P  RX  TX

UNSIGNED_16

Subindex 2:

Motor speed monitoring: Response

Response when tripping the motor speed monitoring
Selection list

(Lenze setting printed in bold)

0 No response
1 Fault
2 Warning

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8