6 motor speed monitoring, 0x2d44 | 0x3544 - motor speed monitoring, Motor speed monitoring – Lenze i700 User Manual
Page 253: 0x2d44:1 0x3544:1, 0x2d44, 0x3544, 8monitoring functions
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
253
8
Monitoring functions
8.6
Motor speed monitoring
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.6
Motor speed monitoring
0x2D44 | 0x3544 - Motor speed monitoring
Sub.
Name
Lenze setting
Data type
Motor speed monitoring: Threshold
8000 r/min
UNSIGNED_16
Motor speed monitoring: Response
1: Trouble
UNSIGNED_8
Subindex 1:
Motor speed monitoring: Threshold
Warning/error threshold for motor speed monitoring
Setting range
(min. value | unit | max. value)
Lenze setting
50
r/min
50000 8000 r/min
Write access CINH OSC P RX TX
UNSIGNED_16
Subindex 2:
Motor speed monitoring: Response
Response when tripping the motor speed monitoring
Selection list
(Lenze setting printed in bold)
0 No response
1 Fault
2 Warning
Write access CINH OSC P RX TX
UNSIGNED_8