2 data header, Data header, 11 appendix – Lenze i700 User Manual

Page 311

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

311

11

Appendix

11.2

Structure of the parameter set file

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.2.2

Data header

"PAR_ParamHeader" header type
If the identification "1" is given for the data area type, the parameter values are successively

arranged in the following layout within the data area:

Byte offset

0

4

8

... Type

Data start

Data size

...

Byte

offset

Meaning

Info

0

Type of the data area

Identification of the data area

Currently only the following values are defined:

• 1: The data area contains parameter values.

"PAR_ParamHeader" header type

• 2: The data area contains error messages of the last

import.

"PAR_ParamErrorHeader" header type

4

Start of the data area

Offset of the data area in [bytes]

(offset from the start of the file).

8

Size of the data area

Size of the data area in [bytes]

Byte offset

0

2

4

6

... Data type size

Index

Subindex

Value

...

Byte

offset

Meaning

Info

0

Data type size of the parameter

Number of bytes which are assigned by the parameter

value.

2

Index of the parameter object

Index of the parameter in the object directory which the

following parameter value belongs to.

4

Subindex of the parameter object

Subindex of the parameter in the object directory which

the following parameter value belongs to.

6

Parameter value

The parameter value assigns the number of data bytes

which are listed under "Data type size of the parameter".

At least, however, always one byte.