5.6
Accepting/adapting plant parameters
The "plant parameters" summarise all parameters which result from the combination of motor and
load. These characterise the transfer behaviour of the entire controlled system including the
required monitoring modes.
• The plant parameters depend on the application in which the controller and motor are used.
• When a Lenze motor is selected, respective plant parameters are suggested for the load-free
operation. This enables the motor to be moved without any load. During operation with a load
it is required to change the plant parameters according to the load. Details on how to determine
the adapted plant parameters are described in the corresponding objects.
Overview of plant parameters
Object
Info
Lenze setting
Control
Axis A
Axis B
Value Unit
Servo
V/f
Max motor speed
6075 r/min
Max current
150 %
Speed controller: Gain
0.00038 Nm/rpm
Speed controller: Reset time
15.0 ms
Speed controller: Rate time
0.00 ms
Speed: Actual speed - filter time
0.6 ms
Motor speed monitoring: Threshold
8000 r/min